Item # HM823211F8YL

Using the 2-valve manifold In normal operation the “isolate” valve is open while the “vent” valve is closed. To remove the instrument, first close the “isolate” valve, then open the “vent” valve to relieve pressure upstream of the “isolate” valve.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard

Description

View product catalog

Additional information

Body Material

Connections-Inlet

Female

Weight

Inlet

1/2" NPT

Max press. at 212 ºF (100 ºC)

6000 psi 413 bar

Max press. at 392 ºF (200 ºC)

4000 psi 275 bar